GEN3.3KW – Laboratory Power Supplies: 3.3KW

Brand: TDK LAMBDA

SKU: HPS-PS-LAB-GEN3.3KW
This product is available globally.
  • High Power Density 3.3kW in 2U.
  • Wide Range of popular worldwide AC inputs, 1Phase (230VAC) & 3Phase (208VAC, 400VAC).
  • Active Power Factor Correction (Single-Phase & Three-Phase AC Input).
  • Output Voltage up to 600V, Current up to 400A.

Description

TDK – Lambda GEN3.3KW

Laboratory Power Supplies: 3.3KW

The Genesys™ – TDK Lambda 2U Full-Rack (GEN-2U) series of 3300W DC Programmable Power Supplies provides high power density (up to 3400W) with a complete set of user-friendly interfaces within a 2U profile.

This series offers Output voltages from 8V (@ 400A) to 600V (@ 5.5A) in a Single-phase 230VAC Input (170-260VAC, 47-63Hz) with Active Power-Factor Correction (0.99 @ rated load) and both a Three-phase 208VAC Input (170-265VAC, 47-63Hz) and Three-phase 400VAC Input (342-460VAC, 47-63Hz) with Active Power-Factor Correction (0.94 @ rated load).

Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant), USB (2.0 compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.

 

SERIES TABLE

ModelOutput Voltage (VDC)Output Current ( A )Output Power ( W )
GEN 8-4000~8V0~4003200
GEN 10-3300~10V0~3303300
GEN 15-2200~15V0~2203300
GEN 20-1650~20V0~1653300
GEN 30-1100~30V0~1103300
GEN 40-850~40V0~853400
GEN 60-550~60V0~553300
GEN 80-420~80V0~423360
GEN 100-330~100V0~333300
GEN 150-220~150V0~223300
GEN200-16.50~200V0~16.53300
GEN 300-110~300V0~113300
GEN 600-5.50~600V0~5.53300

SPECIFICATIONS TABLE

Input Voltage / Frequency (range)Single Phase,230V models: 170~265Vac, 47~63Hz, 3-Phase, 208V models: 170~265Vac,  47~63Hz,3-Phase, 400V models: 342~460Vac, 47~63Hz
Inrush CurrentSingle-Phase and 3-Phase 208V models: Less than 50A , 3-Phase 400V models: Less than 20A
Power FactorSingle Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208/380Vac, rated output   power.
Parallel OperationUp to 4 identical units in master/slave mode
Series OperationUp to 2 identical units. with external diodes. 600V Max to Chassis ground
Operating temp0~50°C, 100% load.
Storage temp-20~85°C
Operating humidity20~90% RH (non-condensing).
Storage humidity10~95% RH (non-condensing).
VibrationMIL-810F, method 514.5 , The EUT is fixed to the vibrating surface.
ShockLess than 20G , half sine , 11mSec. Unit is unpacked.
AltitudeOperating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp.
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m).
RoHS ComplianceComplies with the requirements of RoHS directive.