SPH 60 – Constant Voltage / Constant Current IP65 LED Power Supplies 60W

Brand: NINGBO SNAPPY

SKU: HPS-PS-LLIP20-SPH60
This product is available globally.
  • Wide input range: 90 – 305VAC.
  • High Efficiency up to 89%.
  • Power Factor Correction typically 0.95.
  • IP65 sealed unit.

Description

The SPH60 series power supplies are designed specifically for use with LED applications and available with output voltage options from 12 ~ 48VDC.

These units can operate in Constant Voltage or Constant current mode and output voltage & current is fully adjustable, providing total flexibility.

Electronic protection turns off the power supplies in case of short circuit or overload, as well as open circuit or over temperature.These units are designed to be hard wired in fixed installations, or with an optional power cord, that can be connected to the input terminals with a standard AC plug, for easy installation to any GPO socket/outlet.

SERIES TABLE

ModelOutput (V)         Output (A)Power (W)
SPH60-12A12V5.0A60W
SPH60-15A15V4.0A60W
SPH60-24A24V2.5A60W
SPH60-36A36V1.67A60W
SPH60-48A48V1.25A60W

SPECIFICATIONS TABLE

Input Voltage90 ~ 305VAC
Frequency47~63Hz
Input Current0.33A @ 230VAC
Output V/ASee table
Output Power60 watts
Output Ripple & Noise12V @ 150mV, 15V @ 200mV,
24V @ 280mV, 36 & 48V @ 450 / 550mV
Output Current Tolerance±5%
Line Regulation±3%
Load Tolerance±3%
Rise TimeTypically 30ms ( max 500ms 10-90% voltage )
Hold Up TimeTypically 15mS at 230V input
Power Factor> 0.95
EfficiencyModel Dependent 87 ~ 89%
Inrush CurrentCold start 75A @ 230V
Leakage Current0.75mA @ 230V 50Hz
Protection:
Over Current1.05 ~ 1.3% times rated current. ( Auto Recovery )
Short CircuitHiccup mode with auto recovery
OvervoltageYes. Recycle input power after approx 30sec
Over TemperatureRecycle input power after unit has cooled off
Operating Temp.-40ºC ~ +70ºC  ( 80% load at +70ºC )
Humidity5~95% RH
Temp Coefficient±0.05% per ºC
IP RatingIP65 ( IP66 option)
CoolingFree air convection
ConnectionsInput & Output flying leads
Input Power Cord & Plug – Option
SafetyEN61347-1, EN61347-2-13
Isolation VoltageInput – Output: 5.3KV DC 1min.
EMCEN55015 Class B
ImmunityEN61000-4-2
HarmonicsEN6100-3-2
MTBF5 years per MIL-HDBK-217F ( 25º C )
Mechanical172 x 53 x 37mm  700g
Related Products