HWSP300 – HWSP600 – AC/DC Single Output: 300W – 600W

Brand: TDK LAMBDA

SKU: HPS-PS-HWSP300-600
This product is available globally.
  • 300% Peak Power Capability (5 sec)
  • 24, 36 and 48V Outputs
  • 1008W peak output power HWS300P
  • 1992W peak output power HWS600P
  • Universal Input (85 – 265VAC)

Description

HWSP300 – HWPS600 Series

Peak Power AC/DC Power Supplies Single Output: 300W – 600W

Backed by the same limited lifetime warranty as the HWS series, the HWS300P and HWS600P models offer a 300% peak power rating for 5 seconds. The HWS-P series deliver average power levels of 300 and 600W and are available with 24V, 36V and 48V output voltages.

Key Market Segments & Applications

  • Factory Automation
  • Process Control
  • Semiconductor Fabrication
  • Motor and Pump Drives

 

SERIES TABLE

ModelVoltage VAdjust Range VMax Avg. Current AOvervoltage V
HWS300P-2424V19.2 – 26.412.527.6 – 32.4
HWS600P-2424V19.2 – 26.42527.6 – 32.4
HWS300P-3636V28.8 – 39.68.441.4 – 48.6
HWS600P-3636V28.8 – 39.616.741.4 – 48.6
HWS300P-4848V38.4 – 52.86.355.2 – 64.8
HWS600P-4848V38.4 – 52.812.555.2 – 64.8

SPECIFICATIONS TABLE

Input Voltage Range85 – 265VAC (47 – 63Hz) or 120 – 330VDC
Input Current (Typ)See Datasheet
Inrush Current20 /40  100/200VAC
Power FactorMeets EN61000-3-2
Temperature Coefficient<0.02%/°C
Overcurrent ProtectionSee Datasheet
Overvoltage ProtectionSee Datasheet
Hold Up Time (Typ)20 ms
Leakage Current (max)<0.75mA (Typically 0.2mA at 100VAC)
IndicatorGreen LED = ON
Operating Temperature (with cover)-10°C to +70°C, derate linearly to 50% load from 50°C to 70°C
Storage Temperature-30°C to +85°C
Humidity (non condensing)Operating: 10 – 90%RH, Non operating 10 – 95%RH
CoolingInternal fan
Withstand VoltageInput to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance>100MΩ at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating)10 – 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock< 196.1 m/s2
Safety Agency ApprovalsUL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
Line DipComplies with SEMI F47 (200VAC line only)
Conducted & Radiated EMIEN55011 / EN55022, FCC VCCI Class B
ImmunityIEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11
Weight (Typ)See Datasheet
Size (HxWxD) (with cover)See Datasheet
MTBFSee Datasheet