HWS300 – HWS1500 – AC/DC Single Output: 300W – 1500W

Brand: TDK LAMBDA

SKU: HPS-PS-HWS300-1500
This product is available globally.
  • UL508 approved
  • SEMI F47 Compliant (high line AC)
  • Universal Input (85 – 265VAC)
  • High Efficiency
  • 3.3V, 5V, 6V, 7.5V, 12V, 15V, 24V, 36V, 48V & 60V Output voltage options
Useful Resources

Product Range

SKU Power AC/DC Input Voltage AC/DC Output Voltage 1 AC/DC
HWS300-3300W88 - 264VAC3.3V
HWS300-12300W88 - 264VAC12V
HWS300-48300W88 - 264VAC48V
HWS1500-121500W88 - 264VAC12V
HWS1500-481500W88 - 264VAC48V

Description

HWS300 – HWS1500 Series

AC/DC Power Supply Single Output: 300W – 1500W

The highly reliable 300W, 600W, 1000W and 1500W fan cooled models form part of a very broad HWS product offering ranging from 3.3V to 60V outputs. A 1-6V program input (on select models) can adjust the output from 20-120% of nominal for applications requiring non-standard voltages. Certifications include IEC/EN/UL 60950-1 and UL 508 (most HWS300, 600 models)

Key Market Segments & Applications

  • Factory Automation
  • Test & Measurement
  • Automated Service

Additional information

Weight N/A
Dimensions N/A

SERIES TABLE

ModelVoltage VMax Curr. AEff. Typ (1)%
HWS300-33.3V6074/77
HWS600-33.3V12075/78
HWS1000-33.3V20071/73
HWS1500-33.3V30072/75
HWS300-55V6079/82
HWS600-55V12080/83
HWS1000-55V20076/78
HWS1500-55V30077/81
HWS1000-66V16779/81
HWS1500-66V25079/82
HWS1000-77.5V13480/82
HWS1500-77.5V20081/83
HWS300-1212V2780/83
HWS600-1212V5380/83
HWS1000-1212V8882/85
HWS1500-1212V12582/85
HWS300-1515V2280/83
HWS600-1515V4381/84
HWS1000-1515V7083/85
HWS1500-1515V10083/87
HWS300-2424V1482/85
HWS600-2424V2782/85
HWS1000-2424V4685/87
HWS1500-2424V65/70 (1)84/88
HWS1000-3636V30.785/88
HWS1500-3636V42/46.5 (1)84/88
HWS300-4848V782/85
HWS600-4848V1383/86
HWS1000-4848V2386/88
HWS1500-4848V3286/90
HWS1000-6060V18.485/88
HWS1500-6060V2886/90
(1) 100/220 VAC

SPECIFICATIONS TABLE

Input Voltage Range85 – 265VAC or 120 – 330VDC
Input Current (Typ)SEE DATASHEET
Inrush Current20/ 40
Power FactorMeets EN61000-3-2
Temperature Coefficient<0.02%/°C
Overcurrent Protection>105%
Overvoltage ProtectionYes (see datasheet)
Hold Up Time (Typ)20ms(HWS1500-7 – 16ms)
Leakage Current (max)<0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC)
IndicatorGreen LED = ON
Operating Temperature-10 to +70°C, derate linearly to 50% load from 50 to 70 (2, 3)
Storage Temperature-30 to +85°C
Humidity (non condensing)Operating: 10 –  90%RH, Non operating 10 – 95%RH
CoolingInternal fan
Withstand VoltageInput to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance>100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating)10 – 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock< 196.1 m/s2
Safety Agency ApprovalsUL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Line DipComplies with SEMI F47 (200VAC line only)
Conducted & Radiated EMIEN55011 / EN55022-B, FCC-B, VCCI-B
ImmunityIEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2
Weight (Typ)SEE DATASHEET
Size (HxWxD) (with cover)SEE DATASHEET
MTBFSEE DATASHEET