Single In Line Package DC/DC Converters

For product guidance, customisation, or to find a solution that meets your specific technical requirements, please contact our Technical Sales Engineers.

  • Industry Standard 1” x 1” Footprint
  • Wide Range DC Input 9 - 36 or 18 - 76V
  • High Efficiency - Up to 91%
  • 3.3, 5, 12, 15Vdc Output models
  • Remote on/off, OCP(hiccup)
  • Industry Standard 1” x 1” Footprint
  • Wide Range DC Input 9 - 36 or 18 - 76V
  • High Efficiency - Up to 91%
  • 3.3, 5, 12, 15Vdc Output models
  • Remote on/off, OCP(hiccup)
  • 4:1 Input Voltage: 9-36V, 18-75V
  • Output Voltage: 3.3V, 5V, 9V, 12V, 15V, 24V, ±5V, ±12V, ±15
  • Remote ON OFF
  • 1600vdc input to output Isolation Voltage
  • UL62368-1, EN62368-1, & IEC62368-1 safety approvals
  • 4:1 Input Voltage: 9-36V, 18-75V, 43-160V
  • Output Voltage: 3.3V, 5V, 9V, 12V, 15V, 24V, ±5V, ±12V, ±15
  • EN 50155, EN 45545-2 Railway Standard Approvals
  • Up to 3000VDC Isolation Voltage
  • 4:1 Input Voltage: 9-36V, 18-75V, 43-160V
  • Output Voltage: 3.3V, 5V, 9V, 12V, 15V, 24V, ±5V, ±12V, ±15
  • EN 50155, EN 45545-2 Railway Standard Approvals
  • Up to 3000VDC Isolation Voltage
  • 2MOPP Isolation
  • IEC 60601-1 Medical Safety Approvals
  • DIP16 & SMD16 Package
  • No Minimum Load Required
  • Single and Dual output options
  • 16-160VDC Input Range
  • 5V, 12V, 15V, 24V, 28V, 48V, 53VDC Output Voltage
  • Up to 3000 VAC I/O-isolation Voltage
  • EN 50155 and EN 61373 Approval for Railway Applications
  • Standard 1/2 Brick Package
  • 40W Output Power in a 2"x1" Industrial Standard Package
  • Approved to EN 50155 | EN 45545-2 | IEC/EN/UL 62368-1 Standard
  • 8:1 & 12:1 Input Voltage Range from 9-75V and 14-160V
  • Patented Enhanced Hold-up Function for Supply Interruption and Changeover
  • Adjustable Input Under-Voltage Lockout
  • 3000VDC Input-Output Isolation
  • Operating Temperature: -40°C to +105°C
  • 1 watt output power, PCB mounting.
  • Input options:3.3V. 5V, 12V, 15V & 24VDC.
  • Industry standard footprint.
  • 1000V isolation standard models