DTE60 Series DC/DC Converters 60W

Brand: XP POWER

SKU: DC-DC-CONVERTERS-DIN-RAIL-MOUNT-DTE60
  • Fully Encapsulated Chassis Mount
  • -40 °C to +85 °C Operating Temperature
  • High Efficiency up to 92 %
  • Optional DIN Rail Version
  • Remote On/Off
No Longer Available

This product is no longer available from Helios Power Solutions. Please contact our our Technical Sales Engineers for suitable alternatives.

Product Range

SKU Power DC/DC Input Voltage DC/DC Output Voltage 1 DC/DC
DTE6024S1260W9-36V12V
DTE6048S2460W18-75V24V
DTE40-60-DIN-CLIP60WN/AN/A

DIN Rail clip for DTE40 & DTE60 series – For DIN Rail Mounting

Description

DTE60 Series

Single Output DC/DC Converters: 60W

Main Features

  • Fully Encapsulated Chassis Mount
  • Wide 4:1 Input Range
  • -40 °C to +85 °C Operating Temperature
  • High Efficiency up to 92%
  • Optional DIN Rail Version
  • Remote On/Off
  • EN55032 Conducted Level A With No External Components
  • 3 Year Warranty

Mechanical Details

  1. All dimensions are in inches (mm)
  2. Weight: 0.6 lbs (300 g) approx
  3. Weight for -D version: 0.706 lbs (353 g) approx
  4. Terminal wire size 1.5 mm2 max
  5. Screw terminal torque 4.5 to 6.2 lb-in (0.5 to 0.7 Nm)
  6. Case tolerance: ±0.02 (±0.5)

Additional information

Weight 0.3 kg
Dimensions 112 × 67.8 × 38 mm

Specifications Table

Input
CharacteristicMinimumTypicalMaximumUnitsNotes & Conditions
Input Voltage Range9
18
36
75
VDC
VDC
24 V nominal
48 V nominal
Input CurrentSee Models and Ratings table
Inrush CurrentA
Input FilterPi type
Undervoltage LockoutOn at >9 V. Off <7.5 V
On at >18 V. Off <16.0 V
24 V models
48 V models
Input Surge50
100
VDC
VDC
24 V models for 100 ms
48 V models for 100 ms
Remote On/OffOn: Logic High (3.5-12 V) or open circuit
Off: Logic Low (<1.2 V) or short pin 1 to pin 2
Output
CharacteristicMinimumTypicalMaximumUnitsNotes & Conditions
Output Voltage5.148VSee Models and Ratings table
Initial Set Accuracy±1±2%
Minimum Load0ANo minimum load required
Start Up Delay50ms
Line Regulation±0.2±1.5%
Load Regulation±0.5±1.0%0 – 10% load
Transient Response5% deviationRecovery to within 1% in <250 μs for a 50% load change
at 0.25 A/μs rate
Ripple & Noise100
150
200
mV pk-pk5.1 V model, 20 MHz bandwidth
12 V & 48 V models, 20 MHz bandwidth
48 V model, 20 MHz bandwidth
Short Circuit ProtectionTrip & Restart (hiccup mode), auto recovery
Overload Protection150%Trip & Restart (hiccup mode)
Overvoltage Protection120%Zener diode clamp
Temperature Coefficient0.03%/ °C
General
CharacteristicMinimumTypicalMaximumUnitsNotes & Conditions
Efficiency91%See Models and Ratings table
Isolation2500VDCFor 60 s
Isolation Resistance1000At 500 VDC
Input to Output Capacitance3000pF
Switching Frequency210kHz
Power Density3.4W/in3
Mean Time Between Failure250kHrsMIL-HDBK-217F, +25°C GB
Weight0.6 (300)lb (g)
Environmental
CharacteristicMinimumTypicalMaximumUnitsNotes & Conditions
Operating Temperature -40 +85°CSee derating curve
Storage Temperature -50 +125°C
Case Temperature 95°C
Thermal Impendance
(Case to Ambient)
3.5
1.95
1.61
1.33
°C/WNatural convection
100 LFM
200 LFM
400 LFM
Humidity595%RHNon-condensing
CoolingNatural convection
Shock±3 shocks in each plane, total 18 shocks of 30 g : 11 ms halfsine. Conforms to EN60068-2-27 & EN60068-2-47
Vibration10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
EMC: Emissions
PhenomenonStandardTest LevelNotes & Conditions
ConductedEN55022Level AWith no external components
RadiatedEN55022Level ASee application notes
EMC: Immunity
PhenomenonStandardTest LevelCriteriaNotes & Conditions
ImmunityEN55024
ESD ImmunityEN61000-4-2±4 kV Contact, ±8 kV AirA
Radiated ImmunityEN61000-4-310 V/mA
EFT/BurstEN61000-4-43A
SurgesEN61000-4-53A
Conducted ImmunityEN61000-4-610 VmA