AC Input Voltage range |
85 – 265VAC (47 – 63Hz), 300VAC for 5 seconds |
Power Factor (100 / 200VAC) |
Meets EN61000-3-2 |
Input Current (115/230VAC) (typ) |
See Datasheet |
DC Input |
See Datasheet |
Temperature Coefficient |
<0.02%/°C |
Regulation |
See table series |
Overcurrent Protection |
>105%, 5V & 12V constant current limit & hiccup autorecovery, 24V &48V constant current limit with autorecovery |
Overvoltage Protection |
115-140%, Cycle AC line to reset |
Hold Up Time (typ at full load) |
20ms |
Leakage Current (max) |
750uA maximum, typically 175uA at 115VAC, 63Hz |
Operating Temperature (1) |
-10° to +70°C, derate above 45°C for 50W, 40°C for 100W & 150W, 50°C for 300W & 600W (see graphs below) |
Storage Temperature |
-30° to +75°C |
Operating Humidity (non condensing) |
30 – 90 |
Storage Humidity (non condensing) |
33147 |
Withstand Voltage |
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. |
Isolation Resistance |
>100M at 25°C & 70%RH, Output to Ground 500VDC |
Vibration (non operating) |
10 – 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour |
Shock |
< 196.1 m/s2 |
Safety Agency Approvals (2) (3) |
UL60950-1, CSA60950, EN60950-1, UL:508, CSA C22.2 No.107.1-01, CE Mark |
Conducted & Radiated EMI |
EN55011 / EN55022-B, FCC Class B, VCCI-B |
Immunity |
IEC61000-4-2, -3, -4, -5, -6, -8, -11 |
(1) RWS600B operates down to -20°C.
(2) UL508 & CSA C22.2 No.107.1-01 on RWS50B-5, -12, -24, RWS100B-5, -12, -24, RWS150B-5, -12, -24 & RWS300B-24 only.
(3) Consult Sales Office for use under DC Input conditions. |