ICT300DB-12IRC -48vdc 300A Distribution Panel – Energy Manager Series

Brand: ICT Power

SKU: ICT300DB-12IRC
This product is available globally.
  • Supports negative 48-volt DC applications
  • 300-amp system current / 150 amps per bus
  • Individual output ON/OFF control disconnects user-selectable loads, providing energy savings
  • Full remote monitoring and power control reduces site visits, lowering total cost of ownership and maintenance costs
  • Improve the quality of service and uptime of your network by quickly resolving power issues remotely
  • Increase battery backup time with automatic load shedding by allowing non-critical loads to be removed from the system, maintaining critical loads for longer
  • No additional software required as monitoring and control is provided via an onboard web-based server

Description

ICT300DB-12IRC -48vdc 300A Distribution Panel – Energy Manager Series

Features

  • Supports negative 48-volt DC applications
  • 300-amp system current / 150 amps per bus
  • Dual-feed architecture (Bus A & Bus B)
  • Total of 12 breaker output positions rated up to 50 amps each
  • Six outputs per bus
  • Supports miniature circuit breakers rated up to 63 A (front-mounted)
  • Standard TCP/IP Ethernet communications provides full remote monitoring and control capabilities
  • Network security protocols include HTTPS, SMTP, DNS, TCP, UDP, ICMP, DHCP, ARP, TLS 1.2, SNMP v1/v2c/v3
  • Reporting of total system current (Bus A & Bus B), individual output load current, system voltage, and breaker status
  • Alarm reporting via text, email, or SNMP notification
  • Remote, user-initiated individual output power toggling (ON/OFF)
  • Automatic load shedding disconnects non-critical DC loads when on battery power (user defined)
  • Energy Save disconnect user-selectable loads for energy savings
  • Network watchdog automatically reboots connected routers or switches when no response is received
  • Up to 30 days of data logging
  • Form C alarm contacts
  • 2RU 19-inch rackmount form factor
  • Optional cable management assembly
  • Two-year warranty

Benefits

  • Individual output ON/OFF control disconnects user-selectable loads, providing energy savings
  • Full remote monitoring and power control reduces site visits, lowering total cost of ownership and maintenance costs
  • Improve the quality of service and uptime of your network by quickly resolving power issues remotely
  • Increase battery backup time with automatic load shedding by allowing non-critical loads to be removed from the system, maintaining critical loads for longer
  • No additional software required as monitoring and control is provided via an onboard web-based server

Specifications

Power SpecificationsICT300DB-12IRC
Operating Voltage Range-30 to -60V
System Current Rating300 A
Bus Current Rating150 A each
Number of Outputs per bus6
Max. Output Breaker Rating63 A
Max. Load Output Rating50 A per output
Electro-mechanical Output Relay LogicNormally open

Mechanical

Form Factor2RU – 19 inch rack mount
Dimensions (L x W x H)13.4 x 19.0 x 3.5 in.
339 x 483 x 90 mm
Weight17.0 lbs / 7.7 kg
Input ConnectorsBus bars with dual 5/8″ holes (rear access)
Output ConnectorsIntegrated into breakers (front access)

Environmental

Operating Temperature Range-30°C to +60°C
Output Derating2% /°C (above 50°C)
Storage Temperature-40°C to +70°C
Storage Humidity30-90% RH
CoolingConvection

Design Standards

CSA/CSA US 62368-1, CE, RoHS

Communications

EthernetTCP/IP built-in web server and graphical user interface, 10/100BASE-T, IEEE 802.3 compatible
Supported ProtocolsIPv4, HTTP, HTTPS, SMTP, DNS, TCP, UDP, ICMP, DHCP, ARP, SNMPv1/v2c/v3
SNMP PortsUDP Port 161, SNMP Traps: UDP Port 162
Form CNO/NC/C
Firmware UpgradesRemote over Ethernet
Network SecurityPassword protected, HTTPS encryption, TLS 1.2
Load Output MonitoringCurrent draw measured and reported for each output, user definable under and over current alarms
Email and SMS AlertsMultiple email and text accounts with adjustable intervals
Data LoggingUp to 30 days at one-minute sampling rate, CSV file download, major event logging
Network WatchdogAutonomously ping up to 12 I.P. addresses and power-cycle output if no response, definable settings
Power Cycling and RebootingRemote on/off control of every output individually
Auto Restore ModeReturn to previous output settings after a power loss
Power-up Delay SequencingUser selectable 0 to 60 seconds delay between outputs
Auto Load SheddingEach output user definable, manual or auto restart, low DC voltage triggered

Warranty

Two year warranty

You Might Also Like...