Input | | | | | |
Characteristic | Minimum | Typical | Maximum | Units | Notes & Conditions |
Input Voltage Range | 4.5 10.8 13.5 21.6 | | 5.5 13.2 16.5 26.4 | VDC | 5 V nominal 12 V nominal 15 V nominal 24 V nominal |
Input Reflected Ripple Current | | 20 | | mA pk-pk | Through 12 μH inductor and 47 μF capacitor |
Input Surge | | | 9 18 20 30 | VDC for 100 ms | 5 V nominal 12 V nominal 15 V nominal 24 V nominal |
Output | | | | | |
Characteristic | Minimum | Typical | Maximum | Units | Notes & Conditions |
Output Voltage | 3.3 | | 30 | VDC | See Models and R atings table |
Initial Set Accuracy | | | ±5 | % | At full load |
Minimum Load | 10 | | | % | Minimum load required to meet specified regulation |
Line Regulation | | | ±1.2 | %/1% | Output changes by max of 1.2% for each 1% change in input voltage |
Load Regulation | | | 12/10 | % | For IHL0205S 3V3 and IHL0205S 05/Other Models . From 10% to full load, see application note |
Cross Regulation | | ±5 | | % | On dual output models , when one output is at 25% load and other is varied from 10% load to full load |
Ripple & Noise | | | 150 | mV pk-pk | 20 MHz bandwidth. Measured us ing 10 μF electrolytic in parallel with 0.1 μF ceramic capacitor |
Short Circuit Protection | | | | | Continuous |
Maximum Capacitive Load | | | | | See Models and R atings table |
Temperature Coefficient | | | 0.03 | %/ °C | |
General | | | | | |
Characteristic | Minimum | Typical | Maximum | Units | Notes & Conditions |
Efficiency | | 80 | | % | See Models and R atings table |
Isolation: Input to Output | 5200 | | | VDC | |
Isolation Working Voltage | | | 250 | VAC | |
Isolation Resistance | 109 | | | Ω | |
Isolation Capacitance | | 7 | | pF | |
Switching Frequency | 50 | | 100 | kHz | |
Power Density | | | 23.7 | W/in3 | |
Mean Time Between Failure | 3.3 | | | MHrs | MIL-HDBK-217F, +25°C GB |
Weight | | 0.006 (2.7) | | lb (g) | |
Environmental | | | | | |
Characteristic | Minimum | Typical | Maximum | Units | Notes & Conditions |
Operating Temperature | -40 | | +95 | °C | Derate linearly from 100% at +65 °C to no load at +95 °C |
Storage Temperature | -40 | | +125 | °C | |
Case Temperature | | | +100 | °C | |
Humidity | 2.5 | | 95 | %RH | Non-condensing |
Cooling | | | | | Natural convection |
EMC: Emissions | | | | | |
Phenomenon | Standard | Test Level | | | Notes & Conditions |
Conducted | EN55032 | Class B | | | See application notes |
Radiated | EN55032 | Class B | | | |