Multi Pass 10A & 16A Wall Mount, and 16A Rack Mount Manual Transfer Switch

Brand: Riello UPS

SKU: MANUAL-MAINTENANCE-BYPASS-SWITCH-MULTIPASS-10-16-16R
Note: This product is not available in the following regions: Australia,Asia,Middle East
  • Manual bypass for use in the event of a malfunction or during maintenance
  • Available as 16A rack version or 10A/16A wall mount installation
  • Standard back-feed protection
  • Switching during mains failure

Description

10A & 16A Multi-Pass

External Maintenance Bypass Switch for Uninterruptible Power Supplies

The Multi Pass manual maintenance bypass cuts out Uninterruptible Power Supply  in the event of a fault or during routine maintenance, enabling connected equipment to be powered directly by the mains electricity supply. Multi-Pass ensures that the connected consumers are switched to mains power if a UPS is switched off or goes into blocked status.

Backfeed protection as standard prevents potentially hazardous upstream voltages and ensures safety for any staff or service engineers. Multi Pass is available as a 16 A rackmount version or 10 and 16 A wall-mounted installations, meaning there’s a suitable solution whatever your situation.

Main Features

  • 16 A rack version
  • 10 A and 16 A wall version
  • Standard back-feed protection
  • Switching during mains failure
  • Mains power present LED indicator
  • Available with different socket standards (IEC, British socket, terminal boards).

Onsite installation Example ( Wall Mount Model)

Manual Transfer Switch New Zealand - Helios Power Solutions

Benefits of an external maintenance bypass switch

  • Capability for total isolation for UPS maintenance, with no disturbance to the load.
  • Greatly reduced cost and size when compared to other systems using ‘Key interlocking.’
  • Totally safe and user friendly, simple switching sequence, no risk of back-feeding UPS.
  • Use of electrical interlocking ensures ‘no-break’ transfer without complex & expensive key interlock arrangement.
  • No need for additional Maintenance switches or key exchange boxes (cost savings).
  • Standard system using top quality switchgear, which is readily available (prompt delivery)
  • Can easily be customised to incorporate larger terminals for oversized cables.
  • Can be built to include full MCB/MCCB protection or just isolation depending on site requirements.
  • Unit can also incorporate shunt trip facilities for ‘emergency power off’ (EPO) on input and by-pass switches.
  • Can be installed outside normal hours, by a competent electrician, to enable UPS to be installed during normal hours without a further shutdown.
  • Capability for ‘ two input’ systems giving greater flexibility and security for the critical load.
  • Local MCB/MCCB allow downsizing of cables locally without extra protection devices.