Holiday Trading Hours

Please note our Australia & New Zealand offices / warehouses are closed between Monday 23rd Dec 2024, and Friday 3rd Jan 2025.

Our Middle East & Asia offices are closed Wednesday 1st January 2025 only.

Wishing all of our customers, suppliers, and partners a joyous festive season, and Happy New Year.

Odin Plus RTHigh Temperature On-line AC UPS 1kVA – 3kVA

Brand: Ablerex

SKU: AC-UPS-INDUSTRIAL-SINGLE-PHASE-ODIN-PLUS-RT
Note: This product is not available in the following regions: New Zealand
  • Double Conversion Technology
  • 1kVA, 2kVA & 3kVA output power options
  • Wide Input Voltage and Frequency Window
  • Hot Swappable Battery
  • Rack/Tower Convertible Design

Description

Odin Plus RT

High Temperature – Online Double Conversion Uninterruptible Power Supply 1kVA – 3kVA

The Odin Plus RT Harsh series is a true on-line double conversion UPS featuring all-weather protection to withstand harsh environment conditions.  The Odin Plus RT Harsh series ranges from 1kVA to 3kVA, it can operate in temperatures ranging from -10°C to 55°C without additional cooling or heating equipment and is equip with high temperature sealed lead-acid batteries.

The Odin Plus RT Harsh series features state-of-the-art insulated gate bipolar transistor (IGBT) technology and incorporates capacitors and components designed for a 10-year life span for worry-free dependability.

The Odin Plus RT Harsh series are designed for applications that require shallower mounting depth, higher load capacity and a wide operating temperature range without the need for an AC unit.

SERIES TABLE

ModelPower (-10°C to 40°C)Power (40°C to 55°C)HeightOutput Connections 
Odin Plus RT Harsh 10001000VA/900W600VA/560W2U3 x IEC-C13
Odin Plus RT Harsh 20002000VA/1800W1200VA/1080W3U6 x IEC-C13
Odin Plus RT Harsh 30003000VA/2400W1800VA/1620W4U6 x IEC-C13 + 1 x IEC-C19
Odin Plus RT Harsh 3000D3000VA/2400W1800VA/1620W4U6 x IEC-C13 + 1 x IEC-C19

Specifications Table

Input voltage range *180~300Vac
Input frequency range44Hz ~ 66Hz (Auto-sensing)
PhaseSingle Phase
Output VoltageDefault 230V, adjustable to 220/230/240 Vac
Output WaveformPure sine wave
AlarmsLine Failure / Battery Low / Transfer to Bypass / System Fault
Operation temperature -10°C-55°C
Noise level<50dBA @ 1 meter front
Standard InterfaceRS232, USB, EPO, Extended Battery Connector
Optional communications cardsDry contact, 2nd RS232, USB, SNMP/Web Card
Compatible platformsMicrosoft Window series, Linux, Mac
* Based on load percentage