RWS1000B – RWS1500B – AC/DC Power Supply Single Output: 1000W – 1500W

Brand: TDK LAMBDA

SKU: HPS-AC-DC-RWS-B-SERIES-1000W-1500W
This product is available globally.
  • 85 – 265VAC (47 – 63Hz) Input Range
  • Adjustable outputs
  • Class B Conducted & Radiated EMI
  • Meet the EN 61000-3-2 harmonics and IEC 61000-4 immunity standards
  • 12V, 15V, 24V, 36V &  48V Output voltage options
  • Remote On/Off, Parallel Operation, DC Good and Fan Alarm Signals

Product Range

SKU Power AC/DC Input Voltage AC/DC Output Voltage 1 AC/DC
RWS1000B-121000W88 - 264VAC12V
RWS1000B-241000W88 - 264VAC24V
RWS1000B-481000W88 - 264VAC48V
RWS1500B-121500W88 - 264VAC12V
RWS1500B-241500W88 - 264VAC24V
RWS1500B-481500W88 - 264VAC48V

Description

RWS1000B – RWS1500B Series

TDK – Lambda AC/DC Power Supply 1000W – 1500W

TDK – Lambda RWS1000B and RWS1500B series of AC-DC power supplies. Rated at 1000W and 1500W output power, the units are available with 12V, 15V, 24V, 36V and 48V outputs. Both series feature screw terminal blocks with covers, in place of widely used busbars, allowing easy connection of the output cables. These new models are well suited for general industrial, communications, test and measurement and LED signage applications.

Accepting a wide-range input of 85 to 265Vac, the high power RWS-B series can operate in ambient temperatures of -20 to +60°C, derating linearly above 50°C to 60% load at 60°C. The outputs are adjustable by -15/+10% to accommodate non-standard voltages. The overall case dimensions (W x H x D) for the 1000W are 127 x 63 x 198mm, and 127 x 63 x 261mm for the 1500W models.

Optionally, the 1000/1500W RWS-B power supplies can be ordered with double-sided board coating, reverse airflow, remote on/off, single wire current sharing and DC good and fan alarm signals.

The units are safety certified to IEC/EN/UL 60950-1 with CE marking for the Low Voltage and RoHS2 Directives. The units also comply with EN 55011-B and EN 55032-B conducted and radiated emissions, and meet the EN 61000-3-2 harmonics and IEC 61000-4 immunity standards.

Additional information

Weight N/A
Dimensions N/A

SERIES TABLE

ModelVoltageAdjust Range (V)Max Current (A)Efficiency (typ) % 115/230VAC
RWS1000B-1212V10.2-13.8V8482 / 85
RWS1500B-1212V10.2-13.8V12581 / 85
RWS1000B-1515V12.8-17.2V6782 / 85
RWS1500B-1515V12.8-17.2V10082 / 85
RWS1000B-2424V20.4-27.6V4285 / 88
RWS1500B-2424V20.4-27.6V6385 / 88
RWS1000B-3636V30.6-41.42885 / 88
RWS1500B-3636V30.6-41.44285 / 88
RWS1000B-4848V40.8-52.82185 / 88
RWS1500B-4848V40.8-52.83285 / 88

SPECIFICATIONS TABLE

AC Input Voltage range (1)85 – 265VAC (47 – 63Hz)
DC Input Voltage range*120 – 340VDC*
Inrush Current (100 / 200VAC)60 / 60A
Power Factor (100 / 200VAC)Meets EN61000-3-2 (0.98 / 0.95)
Temperature Coefficient<0.02%/°C
RegulationSee Model Selector
Overcurrent Protection>105%, Constant Current Style.  After 5s unit will shutdown
Overvoltage Protection120-145% (115-125% for 48V), Cycle AC line to reset
Hold Up Time (Typ at 100% load)20ms
Leakage Current (max)<1.2mA
Remote SenseYes
Remote On/OffSee options table
DC Good, Fan AlarmSee options table
Parallel OperationSee options table
Series OperationYes
Operating Temperature-20 to +60°C, derate linearly to 60% load from 50 to 60°C
Storage Temperature-30 to +75°C
Operating Humidity (non condensing)10 – 90%RH
Storage Humidity (non condensing)10 – 90%RH
CoolingInternal Fan, air intake from input/output terminals
Withstand VoltageInput to Ground 2kVAC, Input to Output 4kVAC, Output to Ground 1.5kVAC for 1 min.
Isolation Resistance>100MΩ at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating)10 – 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour
Shock< 196.1 m/s2
Safety Agency CertificationsUL60950-1, CSA60950, EN60950-1, CE Mark
Line DipsSEMI-F47 (200VAC input)
Conducted & Radiated EMIEN55011 / EN55022-B, FCC Class B, VCCI-B
ImmunityIEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2
Weight (Typ)2,000g (1000B) , 3,000g (1000B)
Size (WxHxD)127 x 63 x 198mm (1000B) , 127 x 63 x 261mm (1500B)

Video