New Ultra Wide Input Range DC/DC Converter for Railway Applications

DC Power Supplies for Railway & Rolling Stock Applications - Helios Power Solutions Rolling Stock

Helios Power Solutions announces the QAE100U 100W DC/DC Converter for Railway Applications, as well as Industrial & Telecom applications. The ultra-wide 12:1 input range is available in 9-75VDC or 14-160VDC. With the one single 12:1 ultra-wide input range, the 14-160VDC module can cover all variations of power systems on rolling stock from the one unit. The QAE100U provides a single output with 5, 12, 15, 24, 28, 48 and 53Vdc output voltage, up to 100W, in an industry standard quarter brick PCB mount package.QAE100U is designed to meet EN50155, EN45545-2, IEC62368-1& EN61373. Making them ideal for rolling stock applications. Features User UVLO (under voltage lock out) setting Ideal for applications when running off battery to limit deep battery discharge Up to 3000VAC isolation DC output adjustment -20% to +10% range Remote ON/OFF control and operating range of -40 to 105degC base-plate temperature, with optional heat-sinks available QAE100U Datasheet If you require more information on any of our  services or products please use our contact page or call +61 2 7200 9200 Ultra-Wide Input DC-DC Converters for Railway Applications QAE100U Railway Standards DC/DC Converter: 100W Read more QAE40U Railway Standards DC/DC Converter: 40W Read more QAE60U Railway Standards DC/DC Converter: 60W Read more HAE200U Railway Standards Ultra Wide Input DC/DC Converter: 200W Read more HAE150U Railway Standards Ultra Wide Input DC/DC Converter: 150W Read more DC-DC Converters EN 50155 Approved – Related Products

New Modular OPUS HE Battery Charger Systems for Industrial Applications

Rack Mount & Modular Battery Charger for industrial application

The new Efore OPUS HE family of 19” rack-mount DC power systems are high-efficiency power solutions powered by the new MHE 2kW high-efficiency rectifiers. The 7U rack configuration delivers up to 6 kW of power, while the 12U configuration delivers up to 10 kW. Their robust and reliable fan-free design, modular architecture and use of established components – including the VIDI+ controller and flexible distribution options – ensures the lowest total cost of ownership (TCO) across the 15-20 year expected life span for industrial backup power systems. The OPUS HE series products offer unrivalled efficiency of 97% for minimal environmental impact. They have been designed and optimized for critical infrastructure, distribution and transmission substations, process industries, and railway substations where reliability is always the top priority. New MHE Rectifiers –  5 Warranty MHE rectifiers are convection cooled and require no fans. Rated output power is 2000 W in 48 V – 220 V output versions and 1500 W in 24 V version. Rectifier input is single phase, range 85-300 VAC. 2000 W output power, 24 VDC 1500 W Soft-start generator input feature Active load current sharing Internal over temperature protection Digital communication over CAN bus with Efore VIDI controller Modular Battery Chargers – DC UPS with MHE Rectifiers The MHE rectifier is designed to supply power to industrial and telecom backup power systems. It should only be assembled and used in a system cabinet or sub-rack where human contact with hazardous voltages is prevented.19” 12U Rack delivers maximum 10 kW output power at 48, 60, 110, 125 and 220 VDC and 7.5 kW at 24 VDC output and 19” 7U Rack delivers maximum 6 kW output power at 48, 60, 110, 125 and 220 VDC and 4.5 kW at 24 VDC output. These rack systems support all typical Lead Acid and Ni-Cad battery systems in nominal 24, 48, 60, 110, 125 and 220 voltages. Opus HE 7U Modular Battery Chargers DC UPS Opus HE 12U Modular Battery Chargers DC UPS Proven Quality & Reliability More than ten years providing OPUS  DC systems to the industrial sector in New Zealand, Australia and Asia have reassured the high level of reliability and quality of Opus DC Systems. Power Utilities, Refineries, Mining and  Critical Infrastructure ( Hospitals & Transport Centres) have been few of the applications where our Turnkey  Solutions are installed. Check out the case study below; we had the opportunity to supply six redundant, modular & fanless battery charger systems to the power grid company in Bangladesh. For this specific project, we integrated the first version of Opus MRC Rectifiers and 7U Rack Mount System (still available) which have the same level of reliability but less power density. Case Study Modular & Redundant Battery Chargers for Six Electrical Substations In Bangladesh Contact Our DC Systems Expert Features of CAB 716 48VDC Dual 3.2kW battery charger in a 45U 600mm W x 600mm D cabinet Two 230VAC Mains Input Connections Float Voltage of 56.8VDC configured for NiCd batteries Single DC Distribution with 10 x 10A 2P load breakers with Auxiliary switches Configured for redundancy by two +P95 blocking diodes  Two 100A 2P Battery MCB’s, one for each battery Temperature sensor with temperature compensation A Low Voltage Disconnect set at 40VDC for each charger End customer: Power grid company in Bangladesh MODBUS SNMP Products Installed in CAB 716 OPUS HE DC Power Systems MHE Rectifiers 2000W Read more OPUS HE 7U Modular Battery Charger Up To 6kW Read more SR Series Meter – DC Volt/Amp Meter Read more VIDI+ System Controllers Read more

FCS Series – Low-cost, Open-Frame 40W & 60W Power Supplies

Low-cost, open-frame 40W & 60W power supplies support healthcare, household and ITE applications

Helios Power Solutions has launched two new series of low-profile, open-frame power supplies addressing the need for ultra low-cost 40W and 60W solutions that support a broad range of applications within the medical, domestic/household and ITE/industrial sectors. Most markets are under price pressure these days; the new FCS40 and FCS60 address this need by combining low unit cost with easy integration into multiple end equipment markets with international agency approvals, high efficiency and low emissions. This is further supported by the wide operating temperature (-25°C to +70°C) that allows use in a wide variety of environments. The new FCS40 & 60 supplies offer a single output of either 12, 15, 18, 24, 36 or 48V at efficiencies up to 86%, model dependant. An on-board potentiometer allows the voltage to be trimmed by ±10%, optimising the voltage for specific load requirements or voltage drops. Both the FCS40 and FCS60 carry extensive approvals that ease the task of the designer in obtaining system-level approval for their designs. For medical applications these include IEC/EN/ES60601 offering 2 x Means of Patient Protection (MOPP). The units also include two line input fuses and offer Class II operation, furthering their suitability for medical applications in the home healthcare environment. For ITE & industrial applications the supplies are approved to IEC60950-1 and IEC/EN/cUL62368-1 as well as meeting the needs of the Low Voltage Directive (LVD). IEC60335-1 approval makes the FCS40 and FCS60 applicable to domestic & household applications. As part of XP Power’s ‘Green Power’ range, all of the new supplies minimise the no load power consumption to less than 0.3W, facilitating compliance with the latest environmental legislation. The ability to be convection cooled up to +70°C with de-rating removes the need for a fan from many systems, saving energy, cost and weight as well as improving system reliability. FCS40 Datasheet FCS60 Datasheet Contact Our Sales Engineers

New Products For Your Medical, Radio Access Network & Industrial Applications

EMCO High Voltage DC DC converters

Mars III Series High Performance Redundancy On-line UPS 4.5kVA – 10kVA View Product Unity power factor Patented Backup Runtime Estimation Flexible Battery Configuration (variable number of batteries to best suit your requirement) Easy Parallel Installation Frequency Converter Operation Mode Smart ECO Mode 98% efficiency Generator Compatible Mode Full-time Digital Signal Processor (DSP) Control LCD Mimic Panel Power Range and Runtime Scalability for redundancy or capacity Optional high capacity battery charger for extended runtime Optional Galvanic Isolation Transformer Module / MTBS Box Rack-mounted parallel / Maintenance bypass switch solution Contact Our Sales Engineers 2U Redundant Hot Swap Modular DC Power System Up to 5.6kW 2RU Power Chassis configured at factory for fast, easy installation Choice of 2.8, 3.5 or 5.6 kilowatts of output power Accepts 48 or 24 volt DC hot-swappable ICT 700 watt Power Modules Integrated TCP/IP remote Ethernet communications for monitoring and control Up to twelve fully managed 20A DC load outputs (except 5.6kW model) Monitored outputs can be power cycled individually over Ethernet Dual 100A battery disconnect breakers with LVD (except 5.6kW model) Advanced battery management features including discharge testing and run time remaining (except 5.6kW model) HTTP/HTTPS, SMTP, SNMPv1/v2c/v3 protocols supported 100-300 volts AC input with Power Factor Correction Contact Our Sales Engineers FIRST MULTIDIRECTIONAL POWER INVERTER SIERRA 3KVA – 450KVA 48VDC – 230VAC View Product Sierra Rack secure AC and DC critical loads by taking energy from AC input (Grid) or from the DC Input (Battery). Sierra Rack System has been designed to give quality power, ease of use, and reliability. It can be installed in 19 inch cabinet. Secure AC and DC critical loads Peak shaving function which allows to define the limit of power taken from AC input. If the total load DC+ AC exceed the preset limits the system will compensate with the DC source (battery) 3 phase balancing (Available on 3 Phase Configuration) Low voltage Battery Disconnection (LVD) Contact Our Sales Engineers

IEC protection classes for power supplies

IEC Protection Classes For Power Supplies

Posted by Andrew Bryars on 05 Nov 2018 Power supplies fall into one of three protection classes based on the need, or not, for a protective earth connection:   Class I   – where user protection from electric shock is achieved through a combination of insulation and a protective ground. Class II  – where user protection from electric shock is achieved through two levels of insulation (either double or reinforced) Class III – where the input is connected to a safety extra low voltage (SELV) circuit meaning no further protection is required.   It is important to note the distinction between a class II power supply as described above and a class 2. Limited Power Source (LPS) power supply which relates to the VA rating of the output being limited. A class 2 power supply has a maximum output VA rating of 100VA if the power factor is less than 0.9 or 100W if the power factor is above 0.9. In addition, the maximum allowable output current under any condition is 8A and the maximum output voltage under any condition is 30VDC. The requirements for a class 2 power supply meeting UL1310 are the same as one which meets the limited power source (LPS) requirements of UL60950-1 & UL62368-1. Use of a class II external power supply is straight-forward with only a 2-core mains lead being required for safe operation as the difference between it and a class I product. A class II component or open frame power supply needs no earth connection for safe operation, but the minimum distance from any live part to the enclosure must be observed whether the enclosure is conductive or not to maintain the two levels of protection needed against a single failure in the system. While a class II power supply does not require a protective earth, some lower power class II products find applications in class I systems and some class II applications use a functional earth in the system. The class II supply is designed to meet EMC requirements for emissions and immunity, but if the output of the supply is connected to safety earth or a functional ground it will create a low impedance path for noise altering the power supply’s characteristic performance and it is likely that extra filter components will need to be fitted external to the power supply for emissions compliance.