Holiday Trading Hours

Please note our Australia & New Zealand offices / warehouses are closed between Monday 23rd Dec 2024, and Friday 3rd Jan 2025.

Our Middle East & Asia offices are closed Wednesday 1st January 2025 only.

Wishing all of our customers, suppliers, and partners a joyous festive season, and Happy New Year.

GEN2.4 kW – Laboratory Power Supplies: 2.4 kW

Brand: TDK LAMBDA

SKU: HPS-PS-LAB-GEN2.4KW
This product is available globally.
  • High Power Density 2.4kW in 1U.
  • Wide Range of popular worldwide AC inputs, 1phase (230VAC) & 3phase (208VAC).
  • Auxillary Outputs 5V/0.2A; 15V/0.2A for increased system control functionality.
  • Output Voltage up to 600V, Current up to 300A.

Description

GEN2.4 kW

TDK – Lambda Laboratory Power Supplies: 2.4 kW

The Genesys – TDK Lambda 1U Full-Rack (GEN-1U) series of 2400W DC Programmable Power Supplies provides high power density (up to 2400W) with a complete set of user-friendly interfaces within a 1U (1.75″) profile.

This series offers Output voltages from 8V (@ 300A) to 600V (@ 4.0A) in both Single-phase 230VAC Input (175-265VAC, 47-63Hz) with Active Power-Factor Correction (0.99 @ rated load) and Three-phase 208VAC Input (175-265VAC, 47-63Hz) with Active Power-Factor Correction (0.94 @ rated load) and two Auxiliary Outputs (15.0V @ 0.2A and 5.0V @ 0.2A) for use with Remote Analog Control/Status.

Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.

SERIES TABLE

ModelOutput Voltage (VDC)Output Current ( A )Output Power ( W )
GEN 8-3000~8V0~3002400
GEN 10-2400~10V0~2402400
GEN 16-1500~16V0~1502400
GEN 20-1200~20V0~1202400
GEN 30-800~30V0~802400
GEN 40-600~40V0~602400
GEN 60-400~60V0~402400
GEN 80-300~80V0~302400
GEN 100-240~100V0~242400
GEN 150-160~150V0~162400
GEN 300-80~300V0~82400
GEN 600-40~600V0~42400

SPECIFICATIONS TABLE

Input Voltage / Frequency (range)Single Phase,230V models: 170~265Vac, 47~63Hz,3-Phase, 208V models: 170~265Vac,  47~63Hz
Inrush CurrentSingle-Phase and 3-Phase 208V models: Less than 50A
Power FactorSingle Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208Vac, rated output power.
Parallel OperationUp to 4 identical units in master/slave mode
Series OperationUp to 2 identical units. with external diodes. 600V Max to Chassis ground
Operating temp0~50°C, 100% load.
Storage temp-20~85°C
Operating humidity20~90% RH (non-condensing).
Storage humidity10~95% RH (non-condensing).
VibrationMIL-810F, method 514.5 , The EUT is fixed to the vibrating surface.
ShockLess than 20G , half sine, 11mSec. Unit is unpacked.
AltitudeOperating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp.
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m).
RoHS ComplianceComplies with the requirements of RoHS directive.
You Might Also Like...